Diagnosis Flow
- WARNING LAMP ILLUMINATION INSPECTION
- Turn ignition switch ON.
- Check that warning lamps (such as MIL and oil pressure warning lamp) illuminate.
Do warning lamps illuminate?
- YES: GO TO 2.
- NO: Check ignition power supply system of combination meter. Refer to "POWER SUPPLY AND GROUND CIRCUIT CHECK ".
- SELF-DIAGNOSIS OPERATION CHECK
Perform combination meter self-diagnosis. Refer to "SELF-DIAGNOSIS FUNCTION ".
Does self-diagnosis function operate?
- YES: GO TO 3.
- NO: Check battery power supply of combination meter and ground system. Refer to "POWER SUPPLY AND GROUND CIRCUIT CHECK ".
- ODO/TRIP METER OPERATION CHECK
Check segment display status of odo/trip meter. Refer to "SELF-DIAGNOSIS FUNCTION ".
Is the display normal?
- YES: GO TO 4.
- NO: Replace the combination meter. Refer to "COMBINATION METER ".
- FUEL WARNING LAMP ILLUMINATION CONFIRMATION
During fuel warning lamp check, confirm illumination of fuel warning lamp. Refer to "SELF-DIAGNOSIS FUNCTION ".
Does fuel warning lamp illuminate?
- YES: GO TO 5.
- NO: Replace the combination meter. Refer to "COMBINATION METER ".
- METER CIRCUIT CHECK
During meter circuit check, confirm meter illumination. Refer to "SELF-DIAGNOSIS FUNCTION ".
Is the display normal?
- YES: Go to diagnosis results. Refer to "DIAGNOSIS RESULTS ".
- NO: Replace the combination meter. Refer to "COMBINATION METER ".