FixVault

With Consult-II

  1. Turn ignition switch ON.
  2. Select "DATA MONITOR" mode with CONSULT-II.
  3. Crank engine for at least 2 seconds and run it for at least 5 seconds at idle speed.
  4. If 1st trip DTC is detected, go to DIAGNOSTIC PROCEDURE 

    If 1st trip DTC is not detected, go to next step.

  5. Maintaining engine speed at more than 800 rpm for at least 5 seconds.
  6. If 1st trip DTC is detected, go to DIAGNOSTIC PROCEDURE 
    Fig 1: Identifying Display - Data Monitor
    G02443669Courtesy of NISSAN MOTOR CO., U.S.A.