FixVault

Diagnostic Procedure

  1. CHECK GROUND CONNECTIONS 
    1. Turn ignition switch OFF.
    2. Loosen and retighten three ground screws on the body. Refer to GROUND INSPECTION .
    Fig 1: Locating Ground Screws Of Body
    G02431929Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    • OK: GO TO 2.
    • NG: Repair or replace ground connections.
  2. CHECK EVPA CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER 
    1. Disconnect EVAP control system pressure sensor harness connector.
    2. Check sensor harness connector for water.
      • Water should not exist. 
    3. Fig 2: Disconnecting EVAP Control System Pressure Sensor Harness Connector
      G02431930Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    • OK: GO TO 3.
    • NG: Repair or replace harness connector.
  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR 

    Refer to COMPONENT INSPECTION .

    OK or NG 

    • OK: GO TO 4.
    • NG: Replace EVAP control system pressure sensor.
  4. CHECK INTERMITTENT INCIDENT 

    Refer to "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT . For Wiring Diagram, refer to WIRING DIAGRAM .

    • : INSPECTION END