Power Supply And Ground Circuit Check

  1. CHECK MAIN POWER SUPPLY CIRCUIT FOR SMART ENTRANCE CONTROL UNIT 
    1. Disconnect smart entrance control unit harness connector.
    2. Check voltage between smart entrance control unit harness connector terminals 10, 11 and ground.
      Fig 1: Checking Voltage Between Smart Entrance Control Unit Harness Connector Terminals 10, 11 And Ground
      G02451951Courtesy of NISSAN MOTOR CO., U.S.A.

      Refer to "WIRING DIAGRAM - KEYLES - ".

    OK or NG 

    • OK: GO TO 2.
    • NG: Check the following.
      • 30A fusible link (letter d, located in fuse and fusible link box)
      • 10A fuse (No. 37, located in fuse and fusible link box)
      • M6 circuit breaker
      • Harness for open or short between smart entrance control unit and fuse
  2. CHECK IGNITION SWITCH ACC CIRCUIT 
    1. Disconnect smart entrance control unit harness connector.
    2. Check voltage between smart entrance control unit harness connector terminal 21 and ground while ignition switch is in ACC.
      Fig 2: Checking Voltage Between Smart Entrance Control Unit Harness Connector Terminal 21 And Ground
      G02451952Courtesy of NISSAN MOTOR CO., U.S.A.

      Refer to WIRING DIAGRAM - KEYLES - .

    OK or NG 

    • OK: GO TO 3.
    • NG: Check the following.
      • 10A fuse [No. 1, located in fuse block (J/B)]
      • Harness for open or short between smart entrance control unit and fuse
  3. CHECK GROUND CIRCUIT FOR SMART ENTRANCE CONTROL UNIT 

    Check continuity between smart entrance control unit harness connector terminal 16 and ground.

    Fig 3: Checking Continuity Between Smart Entrance Control Unit Harness Connector Terminal 16 And Ground
    G02451953Courtesy of NISSAN MOTOR CO., U.S.A.

    Refer to "WIRING DIAGRAM - KEYLES - ".

    OK or NG 

    • OK: Power supply and ground circuits are OK.
    • NG: Repair or replace harness.