Fuel Pump Relay

Check continuity between terminals 3 and 5 under the following conditions.

Fig 1: Identifying Fuel Pump Relay Terminals
G02454325Courtesy of NISSAN MOTOR CO., U.S.A.
FUEL PUMP RELAY CONDITIONS AND CONTINUITY REFERENCE

Conditions Continuity
12V direct current supply between terminals 1 and 2 Yes
No current supply NO