FixVault

Overall Function Check (A/T MODELS ULEV AND M/T MODELS)

Use this procedure to check the overall function of the closed loop control. During this check, a DTC might not be confirmed.

WITH GST 

  1. Start engine and warm it up to normal operating temperature.
  2. Set voltmeter probes between ECM terminal 35 [HO2S1 (B1) signal] and ground.
    Fig 1: Checking Voltage Between ECM Connector Terminal 35 [HO2S1 (B1) Signal] And Ground
    G02451413Courtesy of NISSAN MOTOR CO., U.S.A.
  3. Check the following with engine speed held at 2, 000 rpm constant under no- load.
    • The voltage should go above 0.70V at least once.
    • The voltage should go below 0.21V at least once.
  4. If NG, go to "DIAGNOSTIC PROCEDURE (A/T MODELS ULEV AND M/T MODELS) ".