Power Supply And Ground Circuit: Wiring Diagram

Fig 1: Wiring Diagram - Power Supply And Ground Circuit (EC-MAIN-01)
G02450811Courtesy of NISSAN MOTOR CO., U.S.A.

Specification data are reference values and are measured between each terminal and ground.

CAUTION: Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Fig 2: ECM Terminal Value Reference Chart - Power Supply And Ground Circuit
G02450812Courtesy of NISSAN MOTOR CO., U.S.A.