FixVault

Diagnostic Procedure

  1. CHECK GROUND CONNECTIONS 
    1. Turn ignition switch OFF.
    2. Loosen and retighten three ground screws on the body. Refer to "GROUND INSPECTION "
      Fig 1: Locating Body Ground Screws
      G04080459Courtesy of NISSAN NORTH AMERICA, INC.

    OK or NG 

    1. OK : GO TO 2.
    2. NG : Repair or replace ground connections.
  2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER 
    1. Disconnect EVAP control system pressure sensor harness connector.
      Fig 2: Disconnecting EVAP Control System Pressure Sensor Harness Connector
      G04080845Courtesy of NISSAN NORTH AMERICA, INC.
    2. Check sensor harness connector for water.

      Water should not exist  .

    OK or NG 

    1. OK : GO TO 3.
    2. NG : Repair or replace harness connector.
  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR 

    Refer to "COMPONENT INSPECTION ".

    OK or NG 

    1. OK : GO TO 4.
    2. NG : Replace EVAP control system pressure sensor.
  4. CHECK INTERMITTENT INCIDENT 

    Refer to "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT ".

    Refer to "WIRING DIAGRAM ".

    1. : INSPECTION END