Diagnostic Procedure
- CHECK GROUND CONNECTIONS
- Turn ignition switch OFF.
- Loosen and retighten three ground screws on the body. Refer to "GROUND INSPECTION "
OK or NG
- OK : GO TO 2.
- NG : Repair or replace ground connections.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist .
OK or NG
- OK : GO TO 3.
- NG : Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to "COMPONENT INSPECTION ".
OK or NG
- OK : GO TO 4.
- NG : Replace EVAP control system pressure sensor.
- CHECK INTERMITTENT INCIDENT
Refer to "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT ".
Refer to "WIRING DIAGRAM ".
- : INSPECTION END