FixVault

Component Inspection: Condenser

  1. Disconnect condenser harness connector.
  2. Check resistance between condenser terminals 1 and 2.

    Resistance: Above 1 MΩ [at 25°C (77°F)] 

    Fig 1: Checking Resistance Between Connector Terminals
    G04075318Courtesy of NISSAN NORTH AMERICA, INC.