CONSULT-II Reference Value in Data Monitor Mode

Specification data are reference values.

DATA MONITOR MODE REFERENCE

MONITOR ITEM CONDITION SPECIFICATION
BRAKE SW1
(ASCD brake switch)
  • Ignition switch: ON
  • Brake pedal: Fully released (A/T)
  • Clutch pedal and brake pedal:

    Fully released (M/T)

ON
  • Brake pedal: Slightly depressed (A/T)
  • Clutch pedal and/or brake pedal: Slightly depressed (M/T)
OFF
BRAKE SW2
(Stop lamp switch)
  • Ignition switch: ON
  • Brake pedal: Fully released
OFF
  • Brake pedal: Slightly depressed
ON