FixVault

Battery Current Sensor

  1. Reconnect harness connectors disconnected.
  2. Disconnect battery negative cable.
  3. Install jumper cable between battery negative terminal and body ground.
  4. Turn ignition switch ON.
    Fig 1: Identifying Jumper Cable Between Battery Negative Terminal And Body Ground
    G04147606Courtesy of NISSAN MOTOR CO., U.S.A.
  5. Check voltage between ECM terminal 71 (battery current sensor signal) and ground.

    Voltage: Approximately 2.5V 

  6. If NG, replace battery negative cable assembly.
    Fig 2: Checking Voltage Between Terminal 71 And Ground
    G04147591Courtesy of NISSAN MOTOR CO., U.S.A.