CONSULT-II Reference Value in Data Monitor Mode

Specification data are reference values.

DATA MONITOR MODE REFERENCE

MONITOR ITEM CONDITION SPECIFICATION
ACCEL SEN 1
ACCEL SEN 2(1)
  • Ignition switch: ON

    (Engine stopped)

Accelerator pedal: Fully released 0.6 - 0.95V
Accelerator pedal: Fully depressed Less than 4.75V
CLSD THL POS
  • Ignition switch: ON

    (Engine stopped)

Accelerator pedal: Fully released ON
Accelerator pedal: Slightly depressed OFF
(1) Accelerator pedal position sensor 2 signal is converted by ECM internally. Thus, it differs from ECM terminals voltage signal.