FixVault

Diagnostic Procedure

  1. CHECK GROUND CONNECTIONS 
    1. Turn ignition switch OFF.
    2. Loosen and retighten four ground screws on the body.

      Refer to "GROUND INSPECTION ".

      Fig 1: Locating Body Ground Screws M57, M61, M79 And M80
      G04160200Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    OK: GO TO  2.

    NG: Repair or replace ground connections.

  2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER 
    1. Disconnect EVAP control system pressure sensor harness connector.
      Fig 2: View Of EVAP Control System Pressure Sensor, EVAP Canister & EVAP Canister Vent Control Valve
      G04160075Courtesy of NISSAN MOTOR CO., U.S.A.
    2. Check sensor harness connector for water.

      Water should not exist  .

    OK or NG 

    OK: GO TO  3.

    NG: Repair or replace harness connector.

  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR 

    Refer to "COMPONENT INSPECTION ".

    OK or NG 

    OK: GO TO  4.

    NG: Replace EVAP control system pressure sensor.

  4. CHECK INTERMITTENT INCIDENT 

    Refer to "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT ".

    For wiring diagram, refer to "WIRING DIAGRAM ".

    : INSPECTION END