FixVault

Diagnostic Procedure

  1. CHECK GROUND CONNECTIONS 
    1. Turn ignition switch OFF.
    2. Loosen and retighten two ground screws on the body. Refer to "GROUND INSPECTION ".
      Fig 1: Locating M28 & M54 Body Ground Screws
      G04166617Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    OK: GO TO  2.

    NG: Repair or replace ground connections.

  2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER 
    1. Disconnect EVAP control system pressure sensor harness connector.
    2. Check sensor harness connector for water.

      Water should not exist  .

    OK or NG 

    OK: GO TO  3.

    NG: Repair or replace harness connector.

    Fig 2: Identifying EVAP Pressure Sensor And EVAP Vent Control Valve At EVAP Canister
    G04190775Courtesy of NISSAN MOTOR CO., U.S.A.
  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR 

    Refer to "COMPONENT INSPECTION ".

    OK or NG 

    OK: GO TO  4.

    NG: Replace EVAP control system pressure sensor.

  4. CHECK INTERMITTENT INCIDENT 

    Refer to "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT ".

    For wiring diagram, refer to WIRING DIAGRAM .

    : INSPECTION END