FixVault

Procedure For Malfunction B

With CONSULT-II 

  1. Turn ignition switch ON and wait at least 1 second.
  2. Select "DATA MONITOR" mode with CONSULT-II.
  3. Turn ignition switch OFF, wait at least 10 seconds, and then turn ON.
  4. If 1st trip DTC is detected, go to "DIAGNOSTIC PROCEDURE "
    Fig 1: CONSULT-II Display - Data Monitor
    G04900036Courtesy of NISSAN MOTOR CO., U.S.A.

WITH GST 

Follow the procedure "With CONSULT-II" above.

PROCEDURE FOR MALFUNCTION C 

With CONSULT-II 

  1. Turn ignition switch ON and wait at least 1 second.
  2. Select "DATA MONITOR" mode with CONSULT-II.
  3. Turn ignition switch OFF, wait at least 10 seconds, and then turn ON.
  4. Repeat step  3 for 32 times
  5. If 1st trip DTC is detected, go to "DIAGNOSTIC PROCEDURE "
    Fig 2: CONSULT-II Display - Data Monitor
    G04900036Courtesy of NISSAN MOTOR CO., U.S.A.

WITH GST 

Follow the procedure "With CONSULT-II" above.