FixVault

Disassembly and Assembly: Assembly

  1. Temporarily install return spring to striking rod assembly.
    CAUTION: Be careful with the orientation of return spring.
    Fig 1: Identifying Return Spring
    G04889039
  2. Attach one end of the return spring to striking interlock of striking rod assembly while holding return spring.
    Fig 2: Attaching End Of Return Spring To Striking Interlock Of Striking Rod Assembly
    G04889040
    CAUTION:
    • When installing, check that return spring is securely seated in the groove of striking interlock of striking rod assembly.
    Fig 3: Checking Return Spring Seat
    G04889041