FixVault

Front Power Window RH Circuit Check (Power Window and Door Lock/Unlock Switch RH Operation)

  1. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH OUTPUT SIGNAL 
    1. Turn ignition switch OFF.
    2. Disconnect front power window motor RH.
    3. Turn ignition switch ON.
    4. Check voltage between front power window motor RH connector and ground.
      CONNECTOR TERMINAL VOLTAGE SPECIFICATION

      Connector Terminals Condition Voltage (V) (Approx.)
      (+) (-)
      D104 1 Ground UP Battery voltage
      DOWN 0
      2 UP 0
      DOWN Battery voltage
      Fig 1: Checking Voltage Between Front Power Window Motor RH Connector And Ground
      G04927875

    OK or NG 

    OK: Replace front power window motor RH. Refer to "REGULATOR ASSEMBLY ".

    NG: GO TO 2.

  2. CHECK POWER SUPPLY CIRCUIT 
    1. Turn ignition switch ON.
    2. Check voltage between power window and door lock/unlock switch RH connector and ground.

      8 - Ground : Battery voltage 

    OK or NG 

    OK: GO TO  4.

    NG: GO TO 3.

    Fig 2: Checking Power Supply Circuit
    G04927871
  3. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect BCM and power window and door lock/unlock switch RH.
    3. Check continuity between BCM connector (A) and power window and door lock/unlock switch connector (B).
      CONNECTOR TERMINAL CONTINUITY SPECIFICATION

      A B Continuity
      Connector Terminal Connector Terminal
      M20 68 D104 8 Yes
    4. Check continuity between BCM connector (A) and ground.
      CONNECTOR TERMINAL CONTINUITY SPECIFICATION

      A Ground Continuity
      Connector Terminal
      M20 68 No
      Fig 3: Checking Continuity Between BCM And Ground
      G04927872

    OK or NG 

    OK: Check the condition of the harness and the connector.

    NG: Repair or replace harness.

  4. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH OUTPUT SIGNAL 
    1. Turn ignition switch ON.
    2. Check voltage between power window and door lock/unlock switch RH connector and ground.
      CONNECTOR TERMINAL VOLTAGE SPECIFICATION

      Connector Terminals Condition Voltage (V) (Approx.)
      (+) (-)
      D104 7 Ground UP Battery voltage
      DOWN 0
      6 UP 0
      DOWN Battery voltage
      Fig 4: Checking Voltage Between Power Window And Door Lock/Unlock Switch RH Connector D104 Terminals 6, 7 And Ground
      G04927878

    OK or NG 

    OK: GO TO 5.

    NG: GO TO  6.

  5. CHECK FRONT POWER WINDOW MOTOR RH CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect front power window motor RH and power window and door lock/unlock switch RH.
    3. Check continuity between power window and door lock/unlock switch RH connector D104 (A) terminals 6, 7 and front power window motor RH connector D105 (B) terminals 1, 2.

      7 - 1 : Continuity should exist. 

      6 - 2 : Continuity should exist. 

    4. Check continuity between power window and door lock/unlock switch RH connector D104 (A) terminals 6, 7 and ground.

      6 - Ground : Continuity should not exist. 

      7 - Ground : Continuity should not exist. 

      Fig 5: Checking Continuity Between Power Window And Door Lock/Unlock Switch RH Connector D104 Terminals 6, 7 And Ground
      G04927879

    OK or NG 

    OK: Replace front power window motor RH. Refer to "REGULATOR ASSEMBLY ".

    NG: Repair or replace harness.

  6. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH 
    1. Turn ignition switch OFF.
    2. Check continuity between power window and door lock/unlock switch RH terminals.
      CONNECTOR TERMINAL CONTINUITY SPECIFICATION

      Power window and door lock/unlock switch RH Terminals Condition Continuity
      6 8 DOWN Yes
      NEUTRAL or UP No
      11 NEUTRAL or UP Yes
      DOWN No0
      7 8 UP Yes
      NEUTRAL or DOWN No
      12 NEUTRAL or DOWN Yes
      UP No
      Fig 6: Checking Continuity Between Power Window And Door Lock/Unlock Switch RH Terminals
      G04895951

    OK or NG 

    OK: GO TO 7.

    NG: Replace power window and door lock/unlock switch RH. refer to "FRONT DOOR ".

  7. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH GROUND SUPPLY 

    Check continuity between power window and door lock/unlock switch connector and ground.

    CONNECTOR TERMINAL CONTINUITY SPECIFICATION

    Connector Terminals Continuity
    D104 11 Ground Yes
    12 Yes
    Fig 7: Checking Continuity Between Power Window And Door Lock/Unlock Switch Connector And Ground
    G04895952

    OK or NG 

    OK: Check the condition of the harness and the connector.

    NG: GO TO 8.

  8. CHECK GROUND SUPPLY CIRCUIT 
    1. Disconnect main power window and door lock/unlock switch and power window and door lock/unlock switch RH.
    2. Check continuity between main power window and door lock/unlock switch connector (A) and power window and door lock/unlock switch RH connector (B).
      CONNECTOR TERMINAL CONTINUITY SPECIFICATION

      A B Continuity
      Connector Terminal Connector Terminal
      D5 2 D104 11 Yes
      3 12 Yes
    3. Check continuity between main power window and door lock/unlock switch connector (A) and ground.
      CONNECTOR TERMINAL CONTINUITY SPECIFICATION

      A Ground Continuity
      Connector Terminal
      D5 2 No
      3 No
      Fig 8: Checking Ground Supply Circuit
      G04927882

    OK or NG 

    OK: GO TO 9.

    NG: Repair or replace harness.

  9. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH 

    Check continuity between main power window and door lock/unlock switch terminals.

    CONNECTOR TERMINAL CONTINUITY SPECIFICATION

    Main power window and door lock/unlock switch Terminals Condition Continuity
    14 2 Lock switch UNLOCK Yes
    Lock switch LOCK No
    3 Lock switch UNLOCK Yes
    Lock switch LOCK No
    Fig 9: Checking Continuity Between Main Power Window And Door Lock/Unlock Switch Terminals
    G04927883

    OK or NG 

    OK: Repair or replace harness.

    NG: Replace main power window and door lock/unlock switch. Refer to "FRONT DOOR ".