FixVault

CONSULT-II Reference Value in Data Monitor Mode

Specification data are reference values.

MONITOR ITEM CONDITION SPECIFICATION CHART

MONITOR ITEM CONDITION SPECIFICATION
BRAKE SW 1 (ASCD brake switch)
  • Ignition switch: ON
Clutch pedal (M/T) and brake pedal:
Fully released
ON
Clutch pedal (M/T) and/or brake pedal: Slightly depressed OFF
BRAKE SW 2 (Stop lamp switch)
  • Ignition switch: ON
Brake pedal: Fully released OFF
Brake pedal: Slightly depressed ON