FixVault

Diagnostic Procedure

  1. CHECK GROUND CONNECTIONS 
    1. Turn ignition switch OFF.
    2. Loosen and retighten three ground screws on the body. Refer to "GROUND INSPECTION ".
      Fig 1: Checking Ground Connections
      G04895412Courtesy of NISSAN NORTH AMERICA, INC.

    OK or NG 

    OK: GO TO 2.

    NG: Repair or replace ground connections.

  2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER 
    1. Disconnect EVAP control system pressure sensor harness connector.
    2. Check sensor harness connector for water.

      Water should not exist. 

    OK or NG 

    OK: GO TO 3.

    NG: Repair or replace harness connector.

    Fig 2: Identifying EVAP Canister Vent Control Valve And EVAP Control System Pressure Sensor
    G04911422Courtesy of NISSAN NORTH AMERICA, INC.
  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR 

    Refer to "COMPONENT INSPECTION ".

    OK or NG 

    OK: GO TO 4.

    NG: Replace EVAP control system pressure sensor.

  4. CHECK INTERMITTENT INCIDENT 

    Refer to "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT ".

    For Wiring Diagram, refer to WIRING DIAGRAM .

    : INSPECTION END