FixVault

Diagnosis Procedure

  1. CHECK GROUND CONNECTION
    1. Turn ignition switch OFF.
    2. Check ground connection E9. Refer to Ground Inspection in "CIRCUIT INSPECTION ".

    Is the inspection result normal? 

    YES : GO TO 2.

    NO : Repair or replace ground connection.

  2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
    1. Disconnect EVAP control system pressure sensor harness connector.
    2. Check sensor harness connector for water.

      Water should not exist. 

    Is the inspection result normal? 

    YES : GO TO 3.

    NO : Repair or replace harness connector.

  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
    1. Turn ignition switch ON.
    2. Check the voltage between EVAP control system pressure sensor harness connector and ground.
      VOLTAGE SPECIFICATION

      EVAP control system pressure sensor Ground Voltage
      Connector Terminal
      B41 3 Ground Approx. 5V

    Is the inspection result normal? 

    YES : GO TO  6.

    NO : GO TO 4.

  4. CHECK SENSOR POWER SUPPLY CIRCUITS

    Check harness for short to power and short to ground, between the following terminals.

    ECM AND SENSORS TERMINALS REFERENCE

    ECM Sensor
    Connector Terminal Name Connector Terminal
    F13 72 Refrigerant pressure sensor E219 1
    76 CKP sensor (POS) F30 1
    E10 91 EVAP control system pressure sensor B41 3

    Is the inspection result normal? 

    YES : GO TO 5.

    NO : Repair short to ground or short to power in harness or connectors.

  5. CHECK COMPONENTS

    Check the following.

    Is the inspection result normal? 

    YES : GO TO 7.

    NO : Replace malfunctioning component.

  6. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

    Refer to "COMPONENT INSPECTION ".

    Is the inspection result normal? 

    YES : GO TO 7.

    NO : Replace EVAP control system pressure sensor.

  7. CHECK INTERMITTENT INCIDENT

    Refer to "INTERMITTENT INCIDENT ".

    INSPECTION END