Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E9. Refer to Ground Inspection in "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES : GO TO 2.
NO : Repair or replace ground connection.
- CHECK CONNECTOR
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist.
Is the inspection result normal?
YES : GO TO 3.
NO : Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.VOLTAGE SPECIFICATION
EVAP control system pressure sensor Ground Voltage Connector Terminal B41 3 Ground Approx. 5V
Is the inspection result normal?
YES : GO TO 8.
NO : GO TO 4.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.TERMINALS CONTINUITY REFERENCE
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B41 3 E10 91 Existed
Is the inspection result normal?
YES : GO TO 6.
NO : GO TO 5.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B10, E29
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK SENSOR POWER SUPPLY CIRCUITS
Check harness for short to power and short to ground, between the following terminals.
ECM AND SENSORS TERMINALS REFERENCEECM Sensor Connector Terminal Name Connector Terminal F13 72 Refrigerant pressure sensor E219 1 76 CKP sensor (POS) F30 1 E10 91 EVAP control system pressure sensor B41 3 Is the inspection result normal?
YES : GO TO 7.
NO : Repair short to ground or short to power in harness or connectors.
- CHECK COMPONENTS
Check the following.
- Crankshaft position sensor (POS) (Refer to "COMPONENT INSPECTION ".)
- Refrigerant pressure sensor
Is the inspection result normal?
YES : GO TO 13.
NO : Replace malfunctioning component.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.TERMINALS CONTINUITY REFERENCE
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B41 1 E10 96 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES : GO TO 10.
NO : GO TO 9.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B10, E29
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.TERMINALS CONTINUITY REFERENCE
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B41 2 E10 86 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES : GO TO 12.
NO : GO TO 11.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B10, E29
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES : GO TO 13.
NO : Replace EVAP control system pressure sensor.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END