FixVault

CONSULT-III Reference Value in Data Monitor Mode

Specification data are reference values.

CONSULT-III REFERENCE VALUE IN DATA MONITOR MODE

MONITOR ITEM CONDITION SPECIFICATION
ACCEL SEN 1
  • Ignition switch: ON

    (Engine stopped)

Accelerator pedal: Fully released 0.65 - 0.87V
Accelerator pedal: Fully depressed More than 4.3V
ACCEL SEN 2(1)
  • Ignition switch: ON

    (Engine stopped)

Accelerator pedal: Fully released 0.56 - 0.96V
Accelerator pedal: Fully depressed More than 4.0V
CLSD THL POS
  • Ignition switch: ON

    (Engine stopped)

Accelerator pedal: Fully released ON
Accelerator pedal: Slightly depressed OFF
(1) Accelerator pedal position sensor 2 signal is converted by ECM internally. Thus, it differ from ECM terminal voltage.