FixVault

Idle Speed and Ignition Timing

IDLE SPEED AND IGNITION TIMING

Target idle speed CVT No load(1) (In P or N position) 700 ± 50 RPM
M/T No load(1) (in Neutral position) 675 ± 50 RPM
Air conditioner: ON CVT In P or N position 800 RPM or more
M/T In Neutral position
Ignition timing CVT In P or N position 6 ± 5° BTDC
M/T In Neutral position
(1) Under the following conditions: