FixVault

Component Inspection (Fuel Pump)

  1. CHECK FUEL PUMP
    1. Turn ignition switch OFF.
    2. Disconnect "fuel level sensor unit and fuel pump" harness connector.
    3. Check resistance between "fuel level sensor unit and fuel pump" terminals as follows.
      TERMINALS RESISTANCE REFERENCE

      Terminals Resistance
      1 and 3 0.2 - 5.0 Ω [at 25°C (77°F)]

      Is the inspection result normal? 

      YES: INSPECTION END