Terminal and Reference Value for Double Meter

REFERENCE VALUE FOR DOUBLE METER

Terminal No. Wire color Item Condition Voltage (V) (Approx.)
Ignition switch Operation or condition
1 L CAN-H - - -
2 P CAN-L - - -
3 Y Oil pressure sensor power supply ON - 5.5
4 G Oil pressure sensor signal ON When ignition switch is in the ON position. (Engine stopped) 0.5
Engine running. [When the oil pressure is 60 psi (4.22 kg/cm2 )] 2.5
5 R Oil pressure sensor ground ON - 0
6 SB Oil pressure warn out ON Engine oil pressure is below 4.52 psi (0.318 kg/cm2 ) 0.5
Engine oil pressure is above 6.5 psi (0.457 kg/cm2 ) Battery voltage
7 W Battery power supply OFF - Battery voltage
8 P Ignition switch ON or START ON - Battery voltage
9 B Ground ON - 0
10
11 R Illumination control - - Refer to "SYSTEM DESCRIPTION ".
12 V Illumination control - - Refer to "SYSTEM DESCRIPTION ".