FixVault

Component Function Check

  1. PERFORM COMPONENT FUNCTION CHECK
    1. Turn ignition switch ON.
    2. Check the voltage between ECM harness connector and ground under the following conditions.
    TERMINAL VOLTAGE REFERENCE CHART

    ECM Ground Condition Voltage
    Connector Terminal
    F8 69 (PNP switch signal) Ground Selector lever P or N (CVT) Neutral (M/T) Approx. 0 V
    Except above Battery voltage

    Is the inspection result normal? 

    YES: INSPECTION END

    NO: Go to "DIAGNOSIS PROCEDURE ".