FixVault

Component Inspection

  1. CHECK ACCELERATOR PEDAL POSITION SENSOR
    1. Reconnect all harness connectors disconnected.
    2. Turn ignition switch ON.
    3. Check the voltage between ECM harness connector and ground.
    TERMINAL VOLTAGE REFERENCE CHART

    ECM Ground Condition Voltage
    Connector Terminal
    E16 110 (APP sensor 1 signal) Ground Accelerator pedal Fully released 0.6 - 0.9 V
    Fully depressed 3.9 - 4.7 V
    103 (APP sensor 2 signal) Fully released 0.3 - 0.6 V
    Fully depressed 1.95 - 2.4 V

    Is the inspection result normal? 

    YES: INSPECTION END

    NO: GO TO 2.

  2. REPLACE ACCELERATOR PEDAL ASSEMBLY
    1. Replace accelerator pedal assembly.
    2. Perform "SPECIAL REPAIR REQUIREMENT ".

    INSPECTION END