FixVault

Diagnosis Procedure

  1. CHECK GROUND CONNECTION
    1. Turn ignition switch OFF.
    2. Check ground connection E38. Refer to "CIRCUIT INSPECTION ".

    Is the inspection result normal? 

    YES: GO TO 2.

    NO: Repair or replace ground connection.

  2. CHECK ENGINE COOLANT TEMPERATURE SENSOR

    Refer to "COMPONENT INSPECTION ".

    Is the inspection result normal? 

    YES: GO TO 3.

    NO: Replace engine coolant temperature sensor.

  3. CHECK INTERMITTENT INCIDENT

    Refer to "INTERMITTENT INCIDENT ".

    INSPECTION END