FixVault

Component Inspection

  1. CHECK VDC OFF SWITCH
    1. Turn the ignition switch OFF.
    2. Disconnect VDC OFF switch harness connector.
    3. Check the continuity between VDC OFF switch harness connector.
      TERMINALS CONTINUITY REFERENCE CHART

      VDC OFF switch Condition Continuity
      Terminal
      1 - 2 When VDC OFF switch is hold pressed. Existed
      When releasing VDC OFF switch. Not existed

      Is the inspection result normal? 

      YES: INSPECTION END

      NO: Replace VDC OFF switch. Refer to "REMOVAL AND INSTALLATION ".