FixVault

Component Inspection

  1. CHECK THROTTLE POSITION SENSOR
    1. Turn ignition switch OFF.
    2. Reconnect all harness connectors disconnected.
    3. Perform "THROTTLE VALVE CLOSED POSITION LEARNING: SPECIAL REPAIR REQUIREMENT ".
    4. Turn ignition switch ON.
    5. Set selector lever to D (CVT) or 1st (M/T) position.
    6. Check the voltage between ECM harness connector and ground.
      VOLTAGE REFERENCE CHART

      ECM Ground Condition Voltage
      Connector Terminal
      F8 33 (TP sensor 1 signal) Ground Accelerator pedal Fully released More than 0.36V
      Fully depressed Less than 4.75V
      34 (TP sensor 2 signal) Fully released Less than 4.75V
      Fully depressed More than 0.36V

      Is the inspection result normal? 

      YES: INSPECTION END

      NO: Go to 2.

  2. REPLACE ELECTRIC THROTTLE CONTROL ACTUATOR
    1. Replace electric throttle control actuator.
    2. Perform "SPECIAL REPAIR REQUIREMENT ".

      INSPECTION END