Cancel Conditions
VCM stops the normal charging when VCM detects the EVSE is disconnected.
In addition, when the following conditions, VCM temporarily stops the normal charging and enters the wait status.
- When the AC voltage and PWM communication from the EVSE are interrupted.
- When the EVSE connector release switch is pressed.
- When the Li-ion battery temperature reaches 60°C (140°F) or higher.