FixVault

VIAS Control Solenoid Valve

With CONSULT-III

  1. Reconnect harness connectors disconnected.
  2. Turn ignition switch ON.
  3. Perform "VIAS SOL VALVE" in "ACTIVE TEST" mode.
  4. Check air passage continuity and operation delay time under the following conditions.
    AIR PASSAGE CONTINUITY CHECK CONDITIONS CHART

    Condition VIAS SOL VALVE Air passage continuity between (A) and (B) Air passage continuity between (A) and (C)
    ON Yes No
    OFF No Yes
    Fig 1: Checking Air Passage Continuity Between A And B
    G04886586Courtesy of NISSAN MOTOR CO., U.S.A.

    Operation takes less than 1 second. 

Without CONSULT-III

Check air passage continuity and operation delay time under the following conditions.

AIR PASSAGE CONTINUITY CHECK CONDITIONS CHART

Condition Air passage continuity between (A) and (B) Air passage continuity between (A) and (C)
12V direct current supply between terminals 1 and 2 Yes No
No supply No Yes

Operation takes less than 1 second. 

Fig 2: Checking Air Passage Continuity Of VIAS Control Solenoid Valve (Without CONSULT-III)
G04897283Courtesy of NISSAN MOTOR CO., U.S.A.