FixVault

Filament Check

  1. When measuring voltage, wrap tin foil around the top of the negative probe. Then press the foil against the wire with your finger.
    Fig 1: Wrapping Tin Foil Around Top Of Negative Probe
    G04877448Courtesy of NISSAN MOTOR CO., U.S.A.
  2. Attach probe circuit tester (in Volt range) to middle portion of each filament.
    Fig 2: Attaching Probe Circuit Tester (In Volt Range) To Middle Portion Of Filament
    G04877449Courtesy of NISSAN MOTOR CO., U.S.A.
  3. If a filament is burned out, circuit tester registers 0 or battery voltage.
  4. To locate burned out point, move probe to left and right along filament. Test needle will swing abruptly when probe passes the point.
    Fig 3: Identifying Circuit Tester Connection
    G04877450Courtesy of NISSAN MOTOR CO., U.S.A.