FixVault

Inspection Procedure

  1. SELF-DIAGNOSIS RESULT CHECK

    Check the self-diagnosis results.

    SELF-DIAGNOSIS RESULTS

    Self-diagnosis results
    ST ANG SEN COM CIR
    CAN COMM CIRCUIT

    Is the above displayed in the self-diagnosis display items? 

    YES: GO TO 2.

    NO: Inspection End.

  2. CHECK CONNECTOR
    1. Disconnect the ABS actuator and electric unit (control unit) connector, and check the terminals for deformation, disconnection, looseness, and so on. If there is a malfunction, repair or replace the terminals.
    2. Reconnect connector to perform self-diagnosis. Refer to "CONSULT-III FUNCTION (ABS) ".

      Is "CAN COMM CIRCUIT" displayed in the self-diagnosis display items? 

      YES: Refer to "TROUBLE DIAGNOSIS FLOW CHART ".

      NO: Connector terminal connection is loose, damaged, open, or shorted.