FixVault

CONSULT-III Reference Value in Data Monitor Mode

Specification data are reference values.

MONITOR ITEM CONDITION CHART

Monitor item Condition Specification
LOAD SIGNAL
  • Ignition switch: ON
Rear window defogger switch is ON and/or lighting switch is in 2nd position. ON
Rear window defogger switch is OFF and lighting switch is OFF. OFF
HEATER FAN SW
  • Ignition switch: ON
Heater fan: Operating. ON
Heater fan: Not operating. OFF