Diagnosis Procedure

  1. CHECK HORN FUNCTION

    Check horn function with horn switch.

    Do the horn sound? 

    YES >> GO TO 2.

    NO >> Refer to "WIRING DIAGRAM - HORN - ".

  2. CHECK IPDM E/R POWER SUPPLY
    1. Disconnect IPDM E/R connector.
    2. Check voltage between IPDM E/R harness connector and ground.
      (+) (-) Voltage (V) (Approx.)
      IPDM E/R
      Connector Terminal
      E13 34 Ground Battery voltage

      Is the inspection result normal? 

      YES >> Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".

      NO >> GO TO 3.

  3. CHECK IPDM E/R POWER SUPPLY CIRCUIT
    1. Disconnect horn relay connector.
    2. Check continuity between IPDM E/R harness connector and horn relay harness connector.
      IPDM E/R Horn relay Continuity
      Connector Terminal Connector Terminal
      E13 34 E5 1 Existed
    3. Check continuity between IPDM E/R harness connector and ground.
      IPDM E/R Ground Continuity
      Connector Terminal
      E13 34 Not existed

      Is the inspection result normal? 

      YES >> GO TO 4.

      NO >> Repair or replace harness.

  4. CHECK INTERMITTENT INCIDENT

    >> INSPECTION END