FixVault

Data Monitor Mode

DISPLAY ITEMS LIST

X: Standard, -: Not applicable, O: Option
Monitored item (Unit) Monitor item selection Remarks
ECU INPUT SIGNALS MAIN SIGNALS SELECTION FROM MENU
VSP SENSOR (km/h) X - O Secondary speed sensor
ESTM VSP SIG (km/h) X - O -
PRI SPEED SEN (rpm) X - O -
ENG SPEED SIG (rpm) X - O -
SEC HYDR SEN (V) X - O -
PRI HYDR SEN (V) X - O -
ATF TEMP SEN (V) X - O CVT fluid temperature sensor
VIGN SEN (V) X - O -
VEHICLE SPEED (km/h or mph) - X O Vehicle speed recognized by the TCM.
PRI SPEED (rpm) - X O Primary pulley speed
SEC SPEED (rpm) - - O Secondary pulley speed
ENG SPEED (rpm) - X O -
SLIP REV (rpm) - X O Difference between engine speed and primary pulley speed.
GEAR RATIO - X O -
G SPEED (G) - - O -
ACC PEDAL OPEN (0.0/8) X X O Degree of opening for accelerator recognized by the TCM.
For fail-safe operation, the specific value used for control is displayed.
TRQ RTO - - O -
SEC PRESS (MPa) - X O -
PRI PRESS (MPa) - X O -
ATFTEMP COUNT - X O Means CVT fluid temperature. Actual oil temperature °C (°F) cannot be checked unless a numeric value is converted. Refer to ATFTEMP COUNT CONVERSION TABLE .
DSR REV (rpm) - - O -
DGEAR RATIO - - O -
DSTM STEP (step) - - O -
STM STEP (step) - X O -
LU PRS (MPa) - - O -
LINE PRS (MPa) - - O -
TGT SEC PRESS (MPa) - - O -
ISOLT1 (A) - X O Torque converter clutch solenoid valve output current
ISOLT2 (A) - X O Line pressure solenoid valve output current
ISOLT3 (A) - X O Secondary pressure solenoid valve output current
SOLMON1 (A) X X O Torque converter clutch solenoid valve monitor current
SOLMON2 (A) X X O Line pressure solenoid valve monitor current
SOLMON3 (A) X X O Secondary pressure solenoid valve monitor current
RANGE SW 3M (On/Off) X - O Transmission range switch 3 ON-OFF status monitor
RANGE SW 4 (On/Off) X - O Transmission range switch 4 ON-OFF status
RANGE SW 3 (On/Off) X - O Transmission range switch 3 ON-OFF status
RANGE SW 2 (On/Off) X - O Transmission range switch 2 ON-OFF status
RANGE SW 1 (On/Off) X - O Transmission range switch 1 ON-OFF status
BRAKESW (On/Off) X X O Stop lamp switch (signal input via CAN communications)
FULL SW (On/Off) X X O Signal input via CAN communications
IDLE SW (On/Off) X X O
SPORT MODE SW (On/Off) X X O Not mounted but displayed.
STRDWNSW (On/Off) X - O Responds only to vehicles with addle shifter
STRUPSW (On/Off) X - O
DOWNLVR (On/Off) X - O Responds only to vehicles with manual mode
UPLVR (On/Off) X - O
NONMMODE (On/Off) X - O
MMODE (On/Off) X - O
INDLRNG (On/Off) - - O -
INDDRNG (On/Off) - - O "D" position indicator output
INDNRNG (On/Off) - - O "N" position indicator output
INDRRNG (On/Off) - - O "R" position indicator output
INDPRNG (On/Off) - - O "P" position indicator output
CVT LAMP (On/Off) - - O -
SPORT MODE IND (On/Off) - - O Not mounted but displayed.
MMODE IND (On/Off) - - O -
SMCOIL D (On/Off) - - O Step motor coil "D" energizing status
SMCOIL C (On/Off) - - O Step motor coil "C" energizing status
SMCOIL B (On/Off) - - O Step motor coil "B" energizing status
SMCOIL A (On/Off) - - O Step motor coil "A" energizing status
LUSEL SOL OUT (On/Off) - - O -
REV LAMP (On/Off) - X O -
STRTR RLY OUT (On/Off) - - O Starter relay
LUSEL SOL MON (On/Off) - - O -
STRTR RLY MON (On/Off) - - O Starter relay monitor
VDC ON (On/Off) X - O -
TCS ON (On/Off) X - O -
ABS ON (On/Off) X - O -
ACC ON (On/Off) X - O Not mounted but displayed.
RANGE - X O Indicates position is recognized by TCM. Indicates a specific value required for control when fail-safe function is activated.
M GEAR POS - X O Not mounted but displayed.