Component Inspection
- INSPECTION START
Will CONSULT be used?
Will CONSULT be used?
YES: GO TO 2.
NO: GO TO 3.
- CHECK HEATED OXYGEN SENSOR 2
With CONSULT
- Turn ignition switch ON and select "DATA MONITOR" mode with CONSULT.
- Start engine and warm it up to the normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and keep the engine speed between 3, 500 and 4, 000 rpm for at least 1 minute under no load.
- Let engine idle for 1 minute.
- Select "FUEL INJECTION" in "ACTIVE TEST" mode, and select "HO2S2 (B1)/(B2)" as the monitor item with CONSULT.
- Check "HO2S2 (B1)/(B2)" at idle speed when adjusting "FUEL INJECTION" to ± 25%.
"HO2S2 (B1)/(B2)" should be above 0.68 V at least once when the "FUEL INJECTION" is + 25%.
"HO2S2 (B1)/(B2)" should be below 0.18 V at least once when the "FUEL INJECTION" is - 25%.
Is the inspection result normal?
YES: INSPECTION END
NO: Replace malfunctioning heated oxygen sensor 2. Refer to "EXPLODED VIEW ".
- CHECK HEATED OXYGEN SENSOR 2-I
Without CONSULT
- Start engine and warm it up to the normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and keep the engine speed between 3, 500 and 4, 000 rpm for at least 1 minute under no load.
- Let engine idle for 1 minute.
- Check the voltage between ECM harness connector terminals under the following conditions.
ECM Condition Voltage Connector + - Terminal Terminal F8 57 [HO2S2 (bank 1) signal] 59 (Sensor ground) Revving up to 4, 000 rpm under no load at least 10 times The voltage should be above 0.68 V at least once during this procedure. The voltage should be below 0.18 V at least once during this procedure. 58 [HO2S2 (bank 2) signal] Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 4.
- CHECK HEATED OXYGEN SENSOR 2-II
Check the voltage between ECM harness connector terminals under the following conditions.
ECM Condition Voltage Connector + - Terminal Terminal F8 57 [HO2S2 (bank 1) signal] 59 (Sensor ground) Keeping engine at idle for 10 minutes The voltage should be above 0.68 V at least once during this procedure. The voltage should be below 0.18 V at least once during this procedure. 58 [HO2S2 (bank 2) signal] Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 5.
- CHECK HEATED OXYGEN SENSOR 2-III
Check the voltage between ECM harness connector terminals under the following conditions.
ECM Condition Voltage Connector + - Terminal Terminal F8 57 [HO2S2 (bank 1) signal] 59 (Sensor ground) Coasting from 80 km/h (50 MPH) with selector lever in the D position The voltage should be above 0.68 V at least once during this procedure. The voltage should be below 0.18 V at least once during this procedure. 58 [HO2S2 (bank 2) signal] Is the inspection result normal?
YES: INSPECTION END
NO: Replace malfunctioning heated oxygen sensor 2. Refer to "EXPLODED VIEW ".