FixVault

CONSULT Reference Value in Data Monitor Mode

Specification data are reference values.

SPECIFICATION DATA

Monitor item Condition Specification
ACCEL SEN 1 Ignition switch: ON (Engine stopped) Accelerator pedal: Fully released 0.6 - 0.9 V
Accelerator pedal: Fully depressed 4.0 - 4.8 V
ACCEL SEN 2(1) Ignition switch: ON (Engine stopped) Accelerator pedal: Fully released 0.6 - 0.9 V
Accelerator pedal: Fully depressed 3.9 - 4.8 V
CLSD THL POS Ignition switch: ON (Engine stopped) Accelerator pedal: Fully released ON
Accelerator pedal: Slightly depressed OFF
(1) Accelerator pedal position sensor 2 signal is converted by ECM internally. Thus, it differs from ECM terminal voltage.