Power Window and Door Lock/Unlock Switch RH Power Supply Circuit Inspection
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch ON.
- Check voltage between power window and door lock/unlock switch RH connector D104 terminal 8 and ground.
8 - Ground: Battery voltage
OK or NG
OK: Replace power window and door lock/unlock switch RH.
Refer to , "REMOVAL AND INSTALLATION ".
NG: GO TO 2.
- CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM and power window and door lock/unlock switch RH.
- Check continuity between BCM connector (A) and power window and door lock/unlock switch RH connector (B).
A B Continuity Connector Terminal Connector Terminal M20 68 D104 8 Yes - Check continuity between BCM connector (A) and ground.
A Ground Continuity Connector Terminal M20 68 No OK or NG
OK: Check the condition of the harness and the connector.
NG: Repair or replace harness.