EVAP Canister
Check EVAP canister as follows:
- Block port (B ).
- Blow air into port (A ) and confirm that it flows freely out of port (C ).
- Release blocked port (B ).
- Apply vacuum pressure to port (B ) and confirm that vacuum pressure exists at the ports (A ) and (C ).
- Block port (A ) and (B ).
- Apply pressure to port (C ) and check that there is no leakage.