PASSENGER SIDE: Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CHECK ENCODER SIGNAL
- Connect front power window motor RH.
- Turn ignition switch ON.
- Check signal between power window and door lock/unlock switch RH connector D105 and ground with oscilloscope.
Signal name Terminals Signal (Reference value) (+) (-) Power window and door lock/unlock switch RH connector Terminal Encoder signal 1 D105 9 Ground Refer to following signal Encoder signal 2 7 Is the inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: GO TO 2.
- CHECK FRONT POWER WINDOW MOTOR RH POWER SUPPLY
- Turn ignition switch ON.
- Check voltage between front power window motor RH connector D104 and ground.
Terminal Voltage (Approx.) (+) (-) Front power window motor RH connector Terminal D104 2 Ground 10 Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- CHECK HARNESS CONTINUITY 1
- Turn ignition switch OFF.
- Disconnect power window and door lock/unlock switch RH and front power window motor RH.
- Check continuity between power window and door lock/unlock switch RH connector D105 and front power window motor RH connector D104.
Power window and door lock/unlock switch RH connector Terminal Front power window motor RH connector Terminal Continuity D105 2 D104 2 Yes - Check continuity between power window and door lock/unlock switch RH connector D105 and ground.
Power window and door lock/unlock switch RH connector Terminal Ground Continuity D105 2 No Is the inspection result normal?
YES: Replace power window and door lock/unlock switch RH. Refer to "REMOVAL AND INSTALLATION ". After that, refer to "WORK PROCEDURE ".
NO: Repair or replace the harness or connectors.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect front power window motor RH.
- Check continuity between front power window motor RH connector D104 and ground.
Front power window motor RH connector Terminal Ground Continuity D104 4 Yes Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- CHECK HARNESS CONTINUITY 2
- Disconnect power window and door lock/unlock switch RH.
- Check continuity between power window and door lock/unlock switch RH connector D105 and front power window motor RH connector D104.
Power window and door lock/unlock switch RH connector Terminal Front power window motor RH connector Terminal Continuity D105 10 D104 4 Yes Is the inspection result normal?
YES: Replace power window and door lock/unlock switch RH. Refer to "REMOVAL AND INSTALLATION ". After that, refer to "WORK PROCEDURE ".
NO: Repair or replace the harness or connectors.
- CHECK HARNESS CONTINUITY 3
- Disconnect power window and door lock/unlock switch RH.
- Check continuity between power window and door lock/unlock switch RH connector D105 and front power window motor RH connector D104.
Power window and door lock/unlock switch RH connector Terminal Front power window motor RH connector Terminal Continuity D105 9 D104 5 Yes 7 6 - Check continuity between power window and door lock/unlock switch RH connector D105 and ground.
Power window and door lock/unlock switch RH connector Terminal Ground Continuity D105 9 No 7 Is the inspection result normal?
YES: Replace front power window motor RH. Refer to "REMOVAL AND INSTALLATION - FRONT REGULATOR ". After that, refer to "WORK PROCEDURE ".
NO: Repair or replace the harness or connectors.