FixVault

Work Procedure

  1. Check that EVSE is not connected.
    NOTE: If EVSE is connected, the air conditioning system may be automatically activated by the timer A/C function.
  2. Turn the power switch OFF → ON → OFF. Get out of the vehicle. Close all doors (including back door).
  3. Check that the charge status indicator lamp does not blink and wait for 5 minutes or more.
    NOTE: If the battery is removed within 5 minutes after the power switch is turned OFF, plural DTCs may be detected.
  4. Remove 12V battery terminal within 60 minutes after turning the power switch OFF → ON → OFF.
    CAUTION:
    • After all doors (including back door) are closed, if a door (including back door) is opened before battery terminals are disconnected, start over from Step  1.
    • After turning the power switch OFF, if "Remote A/C" is activated by user operation, stop the air conditioner and start over from Step  1.
    NOTE: Once the power switch is turned ON → OFF, the 12V battery automatic charge control does not start for approximately 1 hour.