Component Function Check

  1. CHECK VDC OFF SWITCH OPERATION 

    Operate the VDC OFF switch and check that the VDC OFF indicator lamp in the combination meter turns on/off correctly.

    Condition VDC OFF indicator lamp illumination
    VDC OFF switch ON ON
    VDC OFF switch OFF OFF

    Is the inspection result normal? 

    YES: Inspection End.

    NO: Go to diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".