FixVault

Detailed Flow

  1. COLLECT THE INFORMATION FROM THE CUSTOMER 

    Get the detailed information from the customer about the symptom (the condition and the environment when the incident/malfunction occurred) using the diagnosis worksheet. Refer to "DIAGNOSTIC WORK SHEET ".

    :GO TO 2.

  2. PERFORM SELF-DIAGNOSIS 

    Perform self-diagnosis with CONSULT.

    Is there any DTC displayed? 

    YES: Record or print self-diagnosis results and freeze frame data (FFD). GO TO 3.

    NO: GO TO  4.

  3. PERFORM THE SYSTEM DIAGNOSIS 

    Perform the diagnosis applicable to the displayed DTC of "ABS" with CONSULT. Refer to "DTC NO. INDEX ".

    :GO TO  7.

  4. CHECK THE SYMPTOM THAT IS NOT CONSIDERED A SYSTEM MALFUNCTION 

    Check that the symptom is a normal operation that is not considered a system malfunction. Refer to "DESCRIPTION ".

    Is the symptom a normal operation? 

    YES: GO TO  8.

    NO: GO TO 5.

  5. CHECK THE WARNING LAMP AND INDICATOR LAMP FOR ILLUMINATION 

    Check that the warning lamp and indicator lamp illuminate. Refer to "SYSTEM DESCRIPTION ".

    Is ON/OFF timing normal? 

    YES: GO TO 6.

    NO: GO TO  2.

  6. PERFORM THE DIAGNOSIS BY SYMPTOM 

    Perform the diagnosis applicable to the symptom for "ABS" with CONSULT.

    :GO TO 7.

  7. REPAIR OR REPLACE THE MALFUNCTIONING PARTS 

    Repair or replace the specified malfunctioning parts.

    :GO TO 8.

  8. MEMORY CLEAR 

    Perform self-diagnosis memory clear for "ABS" with CONSULT.

    :GO TO 9.

  9. FINAL CHECK 

    Perform the self-diagnosis again, and check that the malfunction is repaired completely.

    Is no other DTC present and the repair completed? 

    YES: INSPECTION END

    NO: GO TO  3.