FixVault

Power Window Serial Link Check

  1. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH

    1. Remove key and close the front door LH and RH.
    2. Check signal between BCM connector M19 and ground with oscilloscope when door lock and unlock switch (LH and RH) is turned to "LOCK" or "UNLOCK".
    3. Check that signals which are shown in the figure below can be detected during 10 second just after door lock and unlock switch (LH and RH) is turned to "LOCK" or "UNLOCK".
      Terminal Signal
      (Reference Value)
      (+) (-)
      BCM Connector Terminal
      M19 54 Ground
      G04076943Courtesy of NISSAN NORTH AMERICA, INC.

    Is the inspection result normal?

    YES 

    Power window serial link is OK.

    NO 

    GO TO STEP 2. 

  2. CHECK POWER WINDOW SERIAL LINK CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect BCM connector M19.
    3. Check continuity between BCM connector M19 and power window and door lock/unlock switch RH connector D105.
      BCM Connector Terminal Power Window And Door Lock/Unlock Switch RH Connector Terminal Continuity
      M19 54 D105 3 Yes
    4. Check continuity between BCM connector M19 and ground.
      BCM Connector Terminal Ground Continuity
      M19 54 No

    Is the inspection result normal?

    YES 

    Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION .

    NO 

    Repair or replace the harness or connectors.