FixVault

DTC Detection Logic

DTC No. CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition Possible cause
P0643 SENSOR POWER/CIRC
(Sensor reference voltage 'A' circuit high)
ECM detects that the voltage of sensor power supply 1 is excessively low or high.
  • Harness or connectors

    (Battery current sensor circuit is shorted.)

    (CKP sensor circuit is shorted.)

    (TP sensor circuit is shorted.)

    (Refrigerant pressure sensor circuit is shorted.)

    (APP sensor 1 circuit is shorted.)

  • Battery current sensor
  • CKP sensor
  • TP sensor
  • Refrigerant pressure sensor
  • APP sensor