Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK POWER WINDOW DOOR LOCK/UNLOCK SWITCH RH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect power window and door lock/unlock switch RH connector.
- Turn ignition switch ON.
- Check voltage between power window and door lock/unlock switch RH harness connector and ground.
(+) (-) Condition Voltage (V)
(Approx.)Power window and door lock/unlock switch RH Connector Terminal D105 12 Ground Power window main switch (front RH) NEUTRAL 0 UP Battery voltage 11 NEUTRAL 0 DOWN Battery voltage Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH CIRCUIT
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and power window and door lock/unlock switch RH harness connector.
Main power window and door lock/unlock switch Power window and door lock/unlock switch RH Continuity Connector Terminal Connector Terminal D7 12 D105 11 Yes 16 12 - Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D7 12 No 16
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH
Check power window and door lock/unlock switch RH.
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
Check Intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace power window and door lock/unlock switch RH. Refer to REMOVAL AND INSTALLATION .