FixVault

Diagnosis Procedure

Regarding Wiring Diagram information, refer to WIRING DIAGRAM .

  1. CHECK FRONT POWER WINDOW MOTOR RH INPUT SIGNAL

    1. Turn ignition switch OFF.
    2. Disconnect front power window motor RH connector.
    3. Turn ignition switch ON.
    4. Check voltage between front power window motor RH harness connector and ground.
    (+) (-) Condition Voltage (V)
    (Approx.)
    Front power window motor RH
    Connector Terminal
    D104 2 Ground Front power window switch RH NEUTRAL 0
    UP Battery voltage
    1 NEUTRAL 0
    DOWN Battery voltage

    Is the inspection result normal?

    YES 

    Replace front power window motor RH.

    NO 

    GO TO STEP 2  .

  2. CHECK FRONT POWER WINDOW MOTOR RH CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect power window and door lock/unlock switch RH connector.
    3. Check continuity between power window and door lock/unlock switch RH harness connector and front power window motor RH harness connector.
      Power window and door lock/unlock switch RH Front power window motor RH Continuity
      Connector Terminal Connector Terminal
      D105 6 D104 1 Yes
      7 2
    4. Check continuity between power window and door lock/unlock switch RH harness connector and ground.
      Power window and door lock/unlock switch RH Ground Continuity
      Connector Terminal
      D105 6 No
      7

    Is the inspection result normal?

    YES 

    Replace power window and door lock/unlock switch RH. Refer to REMOVAL AND INSTALLATION .

    NO 

    Repair or replace harness.