Input And Output Signals

Major signal transmission between each unit via communication lines is shown in the following table.

Component Signal description
Yaw rate/side/decel G sensor Mainly transmits the following signals to ABS actuator and electric unit (control unit) via communication line* 1 :
  • Yaw rate signal
  • Side G sensor signal
  • Decel G sensor signal
Combination meter Mainly receives the following signal from ABS actuator and electric unit (control unit) via CAN communication:
  • ABS warning lamp signal

* 1: Communication line between yaw rate/side/decel G sensor and ABS actuator and electric unit (control unit)